Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Adicionar filtros








Intervalo de ano
1.
Arq. bras. med. vet. zootec. (Online) ; 72(4): 1185-1196, July-Aug. 2020. tab, graf
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1131484

RESUMO

Glomerular proteinuria is characterized by the loss of high-molecular-weight proteins (HMWPs), while tubulointerstitial proteinuria is characterized by the loss of low-molecular-weight proteins (LMWPs). The objective was to assess the molecular weight of urinary proteins (MWUP) in dogs with naturally acquired CKD and determine the proportion of HMWPs and LMWPs according to CKD stage. Twenty-eight dogs with CKD were recruited and divided into 4 groups based on serum creatinine (Cr) levels (group1: Cr<1,4, n=8; group2: 1,45,0, n=5). The control group consisted of 5 healthy dogs. The MWUP was determined by SDS-PAGE. The urinary protein-to-creatinine ratio (UP/C) was used to quantitatively assess proteinuria. The electrophoresis pattern revealed a proportionally greater loss of HMWPthan of LMWP in all groups with CKD and an increased loss of LMWP in group 4 (P<0.05). These results suggest a predominance of glomerular injuries throughout all stages of CKD in these dogs and an increase in tubulointerstitial injury towards the end-stage of the disease. The results of the present study support the recommendation of SDS-PAGE as an effective technique for the qualitative assessment of proteinuria, as well as a method for assessing the severity and location of renal injury.(AU)


A proteinúria glomerular é caracterizada pela perda de proteínas de alto peso molecular (PAPM), enquanto a proteinúria tubulointersticial se caracteriza pela perda de proteínas de baixo peso molecular (PBPM). O objetivo do trabalho foi determinar o peso molecular das proteínas urinárias (PMPU) de cães com DRC naturalmente adquirida e a proporção de PAPM e PBPM de acordo com o estágio da DRC. Foram utilizados 28 cães com DRC, divididos em quatro grupos, de acordo com o nível sérico de creatinina (cr) (grupo 1: cr<1,4, n=8; grupo 2: 1,45,0, n=5). O grupo controle era composto por cinco cães saudáveis. O PMPU foi determinado por SDS-PAGE. A relação proteína:creatinina urinária (RPCU) foi utilizada como um método quantitativo de proteinúria. A eletroforese revelou uma perda proporcionalmente maior de PAPM, quando comparada às PBPM, em todos os grupos de DRC, bem como uma perda crescente de PBPM no grupo 4 (P<0,05). Esses resultados sugerem uma predominância de lesão glomerular em todos os estágios de DRC nesses cães e uma progressão crescente na lesão túbulo-intersticial no estágio terminal da doença. Os resultados deste estudo reafirmam a recomendação de que a eletroforese de proteínas urinárias é uma técnica qualitativa efetiva de avaliação da proteinúria, bem como um método que permite avaliar a extensão e a localização da lesão renal.(AU)


Assuntos
Animais , Cães , Proteinúria/diagnóstico , Proteinúria/veterinária , Creatinina/análise , Insuficiência Renal Crônica/veterinária , Eletroforese/veterinária
2.
Arq. bras. med. vet. zootec. (Online) ; 70(6): 1784-1792, nov.-dez. 2018. tab, ilus
Artigo em Português | LILACS, VETINDEX | ID: biblio-970427

RESUMO

Foram incluídos 76 gatos domésticos com diferentes graus (I a IV) de lesões em cavidade oral, os quais foram avaliados clinicamente e tiveram coletadas amostras de sangue e suabes da cavidade oral. A maioria dos gatos portadores de CGE eram machos, castrados, adultos, sem raça definida e com estilo de vida confinado. Os sinais clínicos observados e associados à gravidade da inflamação na cavidade oral foram halitose (98,7%); ptialismo (22,4%); hemorragia bucal (9,2%) e úlcera na parte superior dos lábios (2,6%); desconforto à manipulação da cavidade oral (44,7%) e perda dentária (55,3%). A maioria dos gatos avaliados foi classificada no grau II (43,4%). Não se observou diferença significativa nos resultados do eritrograma dos gatos portadores de CGE, independentemente da gravidade das lesões e da sintomatologia clínica. Entretanto, observou-se neutrofilia (21,1%) e aumento de proteínas plasmáticas totais (47,3%), na maioria dos animais de grau II, sugerindo que esses parâmetros laboratoriais, quando aumentados, possam estar associados a graus menos graves de CGE. A análise das lâminas de citologia da cavidade oral dos gatos demonstrou que a presença de Simonsiella spp. foi mais frequente nos animais incluídos no grau IV, entretanto não é possível afirmar que essa bactéria esteja relacionada à gravidade das lesões.(AU)


Seventy six domestic cats classified with different scores (I to IV) of oral lesions have been included in the study, being clinically examined and having blood samples and oral cavity swabs collected. Most cats diagnosed with Gingivostomatitis Complex (GSC) were male, neutered, adult, DSH, and lived confined. Clinical signs observed and related to the severity of mouth inflammation were halitosis (98.7%), ptyalism (22.4%), oral hemorrhage (9.2%), and upper lip ulcers (2.6%); discomfort during mouth examination (44.7%) and tooth loss (55,3%). Most cats have been classified as score II (43.4%). The red blood cell count showed no significant statistical difference regardless the different scores of oral lesions and clinical symptoms. However, the leukogram showed neutrophilia (21.1%) and plasmatic proteins had an increased level (47.3%), in most of the animals classified as score II, suggesting that these parameters, when increased, may be associated to less severe GSC scores. Oral cavity microscope slides analysis showed that Simonsiella spp. have been more frequent in the cytology of the score IV animals, however, it does not allow us to correlate the presence of the bacteria with the severity lesions degree.(AU)


Seventy six domestic cats classified with different scores (I to IV) of oral lesions have been included in the study, being clinically examined and having blood samples and oral cavity swabs collected. Most cats diagnosed with Gingivostomatitis Complex (GSC) were male, neutered, adult, DSH, and lived confined. Clinical signs observed and related to the severity of mouth inflammation were halitosis (98.7%), ptyalism (22.4%), oral hemorrhage (9.2%), and upper lip ulcers (2.6%); discomfort during mouth examination (44.7%) and tooth loss (55,3%). Most cats have been classified as score II (43.4%). The red blood cell count showed no significant statistical difference regardless the different scores of oral lesions and clinical symptoms. However, the leukogram showed neutrophilia (21.1%) and plasmatic proteins had an increased level (47.3%), in most of the animals classified as score II, suggesting that these parameters, when increased, may be associated to less severe GSC scores. Oral cavity microscope slides analysis showed that Simonsiella spp. have been more frequent in the cytology of the score IV animals, however, it does not allow us to correlate the presence of the bacteria with the severity lesions degree.(AU)


Assuntos
Gatos/anormalidades , Técnicas de Laboratório Clínico , Gengivite/veterinária
3.
Arq. bras. med. vet. zootec ; 68(3): 611-619, tab, graf
Artigo em Português | LILACS, VETINDEX | ID: lil-785682

RESUMO

Após validação de dois diferentes métodos de mensuração de pressão arterial sistólica (PAS) não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro) em 12 gatos hígidos anestesiados de mesma faixa etária, os métodos não invasivos foram avaliados e comparados em 24 gatos hígidos e conscientes, divididos em quatro grupos de idade. Em cada animal, procedeu-se à mensuração da pressão pelos métodos Doppler e oscilométrico. O método oscilométrico foi o primeiro a ser realizado, e, logo em seguida, o método Doppler. Os valores considerados foram obtidos das médias de sete medidas consecutivas para cada método, com intervalo de 30 segundos entre elas. A primeira medida e as medidas discrepantes (variação ˃ 20% PAS), obtidas com sinais óbvios de estresse e/ou com movimentação do animal, foram descartadas. Os métodos de mensuração oscilométrico e Doppler, embora tenham apresentado médias estatisticamente diferentes em todos os grupos, quando comparados em cada grupo, apresentaram uma correlação significativa, alta e positiva. Ou seja, sempre que for obtido um valor elevado por um método, o mesmo fato ocorrerá com o outro método e vice-versa. Clinicamente, a diferença observada não é relevante, uma vez que a diferença média dos valores obtida pelos dois métodos, em cada grupo, foi menor que 1,1%.(AU)


After two different validation systolic blood pressure measurement methods (PAS), not invasive or indirect (oscillometric and doppler vascular) with invasive or direct (arterial catheterization - Gold Standard) in 12 anesthetized healthy cats of the same age group, not invasive methods were evaluated and compared in 24 healthy conscious cats, divided into four age groups. In each animal, we proceeded to measure the pressure by Doppler and oscillometric methods. The oscillometric method was the first to be performed, and, shortly thereafter, the doppler method. The values considered were obtained from averages from seven consecutive measurements for each method with an interval of thirty seconds between them. The first measurement and disparate measurements (range ˃ 20% PAS) obtained with obvious signs of stress and / or animal movement were discarded. Methods of oscillometric and doppler measurement, although statistically different averages were shown in all groups when compared, each group showed a significant high positive correlation, meaning that when a high value is obtained by a method, the same occurs with the other method, and vice versa. Clinically, the observed difference is not relevant since the mean difference values obtained by the two methods, in each group was lower than 1.1%.(AU)


Assuntos
Animais , Gatos , Anestesia/veterinária , Pressão Arterial , Pressão Sanguínea , Cateterismo/veterinária , Oscilometria/veterinária , Hipertensão/veterinária , Fenômenos Fisiológicos
4.
Arq. bras. med. vet. zootec ; 66(4): 1051-1059, 08/2014. tab, graf
Artigo em Português | LILACS | ID: lil-722564

RESUMO

Foram avaliados e comparados, para fins de validação, dois diferentes métodos de mensuração de pressão arterial sistólica (PAS), não invasivos ou indiretos (oscilométrico e Doppler vascular) com o invasivo ou direto (cateterização arterial - padrão ouro), em 12 gatos hígidos anestesiados de idade variando entre sete meses e dois anos. Em cada animal, procedeu-se à mensuração simultânea da pressão não invasiva e da invasiva. O método oscilométrico foi comparado, por meio de sete medidas consecutivas, com intervalo de 30 segundos entre elas, com o método invasivo, e, logo em seguida, o método Doppler foi comparado ao método invasivo da mesma maneira. Concluiu-se que o método oscilométrico é estatisticamente igual ao método invasivo, enquanto o Doppler difere de ambos. Entretanto, pela forte correlação positiva entre os métodos Doppler e invasivo, foi possível criar um fator de correção (equação de regressão linear) para se determinar o valor da pressão invasiva, a partir do valor obtido pelo método Doppler. Para obtenção de valores mais fidedignos, recomenda-se a utilização desse fator de correção quando o método Doppler for utilizado para mensuração de PAS em gatos anestesiados.


For validation purposes, two different methods of measurement of systolic blood pressure (SBP), noninvasive or indirect (oscillometric and vascular doppler), direct or invasive (arterial catheterization - the gold standard) were evaluated and compared in 12 healthy anesthetized cats, varying between seven months to two years old. In each animal, we proceeded to the simultaneous noninvasive and invasive measurement of pressure. The oscillometric method was compared by means of seven consecutive measurements with an interval of 30 seconds between them, with the invasive method, and soon after, the doppler method was compared to the invasive method in the same way. It was concluded that the oscillometric method is statistically equal to the invasive method, whereas doppler differs from both. However, due to the strong positive correlation between doppler and invasive methods, it was possible to create a correction factor (linear regression) to determine the value of invasive pressure from the value obtained by the doppler method. To obtain more reliable figures, it is recommended to use this correction factor when the doppler method is used to measure SBP in anesthetized cats.


Assuntos
Animais , Gatos , Anestesia/veterinária , Determinação da Pressão Arterial/veterinária , Artéria Femoral , Gatos/fisiologia , Monitores de Pressão Arterial/veterinária , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Pressão Arterial , Equipamentos e Provisões/veterinária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA